{"product_id":"d03-ng6-wiring-box-3-position-hydraulic-electrical-solenoid-valve-21-gpm-4560-psi-12vdc-24vdc-110vac","title":"D03 (NG6): Wiring Box 3-Position Hydraulic Electrical Solenoid Valve:  18 GPM: 4560 psi: 12VDC 24VDC 110VAC","description":"\u003cp\u003e\u003cspan\u003eFor a larger view of images, right click on the image and select \"Open in a new tab\" \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eLink to: \u003ca href=\"https:\/\/drive.google.com\/file\/d\/1W-LcpON7nAKT1LCZrUQRBdyMbBzCsk7s\/view?usp=sharing\" target=\"_blank\"\u003eCatalog\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eHydraulic Directional Control Valves are used to control the hydraulic oil flow path to an actuator (cylinder or motor).  The variety of spool options available allow for various movement types based on the application requirements of your cylinder or motor.  \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-size: 0.875rem;\"\u003eProven h\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-size: 0.875rem;\"\u003eigh quality robust valve design successfully designed into many high volume applications.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFluidhaus valve coils are fully encapsulated by injection molding.  This is a more reliable sealing process than traditional potting, with better protection against moisture, vibration, temperature and greater life cycles.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eWiring terminal box with 1\/2\" (G1\/2\") conduit connection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eD03 (NG6) Cetop 3 mounting.  Can be mounted to standard available subplates and bar manifolds.\u003c\/li\u003e\n\u003cli\u003eMaximum flow of 21 gpm for DC power and 15.8 gpm for AC (reference Solenoid Power limit chart)\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure = 4560psi (315 Bar)\u003c\/li\u003e\n\u003cli\u003e3-position, 4-way, Spring centered, energize to shift\u003c\/li\u003e\n\u003cli\u003eDouble solenoid operated\u003c\/li\u003e\n\u003cli\u003eRemovable Coil\u003c\/li\u003e\n\u003cli\u003eLED illuminate’s when power is supplied to the connector\/coil. \u003c\/li\u003e\n\u003cli\u003eValve can be mounted in any direction\u003c\/li\u003e\n\u003cli\u003eLED illuminate’s clear connector housing when power is supplied to the connector\/coil. \u003c\/li\u003e\n\u003cli\u003eNBR Buna Seals\u003c\/li\u003e\n\u003cli\u003eFour fastening screws included, M5x45mm long\u003c\/li\u003e\n\u003cli\u003eWhite label with no logo for OEM manufacturers.\u003c\/li\u003e\n\u003cli\u003eWeight = 4.3 lbs (1.95 kg)\u003c\/li\u003e\n\u003cli\u003eSolenoid Power: DC=30watts, AC=50VA holding and 220VA inrush\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cu\u003eSolenoid Voltage:\u003c\/u\u003e 12VDC, 24VDC, 110VAC (50 or 60 hz), 220VAC (50 or 60 hz)\u003c\/p\u003e\n\u003cp\u003e\u003cu\u003eSpool Configurations:\u003c\/u\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC:\u003c\/strong\u003e  Closed center spool, all ports blocked when centered.\u003cstrong\u003e\u003cbr\u003e\u003cimg data-mce-fragment=\"1\" style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"79\" width=\"157\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0497\/1649\/4499\/files\/Closed_Center_Symbol_3d9083b5-cdfb-4d26-9155-0049360ce2ed_480x480.jpg?v=1616792450\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003eUseful to switch actuator directions and to fully stop cylinder or motor when centered.  Make sure there is a relief valve to protect overrunning loads from spiking the pressure during sudden stops when centering.  Note that there is some leakage of oil across the spool in the center position and slow drifting of the actuator could be possible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eM\u003c\/strong\u003e:  Motor spool, A and B ports to tank and P port blocked when centered. \u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"75\" width=\"159\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0497\/1649\/4499\/files\/Motor_Center_Symbol_3938b3e3-6890-44c1-9a21-a87f2efd67a1_480x480.jpg?v=1616792547\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eActuators will move freely from external forces when the valve is in the center position.  Motors and cylinders will coast to a stop when centering.  Adding an A\u0026amp;B port P.O. check valve under this valve will ensure a positive stop and hold the position of a motor and cylinder for longer durations than with just a closed center spool valve C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eT\u003c\/strong\u003e:  Tandem Spool, A and B ports closed and P to T in center position:\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"69\" width=\"145\" style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0497\/1649\/4499\/files\/T_Spool_e493f946-f7b5-46d8-b7b3-5ef4169f794e_480x480.jpg?v=1616792608\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eActuators will stop in center position and the supply pressure will be directed to tank.  Commonly used with fixed displacement gear pumps so pressure can flow direct to tank and not build up heat by blowing across a relieve valve as would be needed with the M and C spool.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eH:\u003c\/strong\u003e Open Center Spool, A, B P and T ports connected in center.\u003c\/p\u003e\n\u003cp\u003eActuators will freely move when valve is de-energized and spring centered.  Pressure and all ports will drain to tank.  Energize solenoid “a” and “b” to change direction of actuator.\u003cstrong\u003e\u003cbr\u003e\u003cimg data-mce-fragment=\"1\" style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"71\" width=\"149\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0497\/1649\/4499\/files\/H_Spool_480x480.jpg?v=1616792690\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR:\u003c\/strong\u003e Regeneration Spool: Closed ports in spring center position.  When “b” side shifted the rod side of a cylinder will connect to the piston side combining the flows for a higher speed extension of the cylinder.\u003c\/p\u003e\n\u003cp style=\"padding-left: 180px;\"\u003e\u003cimg height=\"79\" width=\"141\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0497\/1649\/4499\/files\/R_Spool_480x480.jpg?v=1634939483\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eActuator will stop in the center position.  When “a” side is shifted, Pressure will go to the B port (typically rod side of cylinder) and the A port (typically piston side of cylinder) will go to tank for retracting the cylinder.  When the “b” side is shifted the rod side and piston side are connected to pressure in regeneration, creating a higher extension flow.  Note the extend for will be reduced by the area of the rod.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eHigh volume OEM series production available per request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluidhaus","offers":[{"title":"C-All Ports Closed in Center Position \/ 12VDC","offer_id":43732422623409,"sku":"VSD6-C-12CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"C-All Ports Closed in Center Position \/ 24VDC","offer_id":43732422656177,"sku":"VSD6-C-24CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"C-All Ports Closed in Center Position \/ 110VAC","offer_id":43732422688945,"sku":"VSD6-C-110CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"C-All Ports Closed in Center Position \/ 220VAC","offer_id":43732422721713,"sku":"VSD6-C-220CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"M-Motor-Center A\u0026B to Tank and Pressure Blocked \/ 12VDC","offer_id":43732422754481,"sku":"VSD6-M-12CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"M-Motor-Center A\u0026B to Tank and Pressure Blocked \/ 24VDC","offer_id":43732422787249,"sku":"VSD6-M-24CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"M-Motor-Center A\u0026B to Tank and Pressure Blocked \/ 110VAC","offer_id":43732422820017,"sku":"VSD6-M-110CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"M-Motor-Center A\u0026B to Tank and Pressure Blocked \/ 220VAC","offer_id":43732422852785,"sku":"VSD6-M-220CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"T-Tandem-Center A\u0026B Blocked and Pressure to Tank \/ 12VDC","offer_id":43732422885553,"sku":"VSD6-T-12CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"T-Tandem-Center A\u0026B Blocked and Pressure to Tank \/ 24VDC","offer_id":43732422918321,"sku":"VSD6-T-24CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"T-Tandem-Center A\u0026B Blocked and Pressure to Tank \/ 110VAC","offer_id":43732422951089,"sku":"VSD6-T-110CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"T-Tandem-Center A\u0026B Blocked and Pressure to Tank \/ 220VAC","offer_id":43732422983857,"sku":"VSD6-T-220CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"H-All Ports Open to Tank in Center \/ 12VDC","offer_id":43732423016625,"sku":"VSD6-H-12CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"H-All Ports Open to Tank in Center \/ 24VDC","offer_id":43732423049393,"sku":"VSD6-H-24CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"H-All Ports Open to Tank in Center \/ 110VAC","offer_id":43732423082161,"sku":"VSD6-H-110CL","price":175.0,"currency_code":"USD","in_stock":true},{"title":"H-All Ports Open to Tank in Center \/ 220VAC","offer_id":43732423114929,"sku":"VSD6-H-220CL","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0497\/1649\/4499\/files\/1Main_43d85dc7-bc99-42c7-af07-b5cb5d64c7a4.jpg?v=1712859975","url":"https:\/\/hydraulicsinstock.com\/es-ca\/products\/d03-ng6-wiring-box-3-position-hydraulic-electrical-solenoid-valve-21-gpm-4560-psi-12vdc-24vdc-110vac","provider":"Fluidhaus","version":"1.0","type":"link"}